ZONING AND SITE REQUIREMENTS SUMMARY
PZR REPORTĀ® FOR:
100 WEST CHANNEL ISLAND BOULEVARD

PORT HUENEME, CALIFORNIA

Prepared For:
LENDER
Date: Final - 10/7/2010
PZR SITE NUMBER: 12345-1

The Planning & Zoning Resource Corporation
100 NORTH EAST 5th STREET

OKLAHOMA CITY, OKLAHOMA 73104

(405 ) 840-4344

(405 ) 840-2608 FAX

ZONING AND SITE REQUIREMENTS SUMMARY
I. Property Location and Size
1. Jurisdiction: City of Port Hueneme, CA
2. Name: 100 West Channel Island Boulevard
3. Address: 100 West Channel Island Boulevard
4. Size: 9.34 Acres or 406,850.4 Sq. Ft. +/-, per Survey
II. Existing Land Use and Zoning
1. Date of Existing Ordinance: December 7, 2009
2. Existing Zoning Designation: "C-1 (PD)" General Commercial
(Planned Development)
3.Adjacent Zoning Designation and or Uses if Applicable: To the North: "C-1" and "R-1"

To the East: "C-1"

To the South: Navy Base

To the West: City of Oxnard

4. Existing Land Use: Shopping Center with Restaurants,
Liquor Store, Retail, Bank, Personal
Services and Professional Offices.
Is The Existing Use in Conformance? Yes, as Permitted Uses by virtue of the
Permitted Uses within the "C-1" District.
(See Chapter 4, Part E, Section 10481 for
Code reference)
III. Zoning Regulations
1. Are copies of zoning regulations available for this site? Yes, Attached
2. If any aspect of the property is not in conformance with current zoning, does the municipality provide ordinances dealing with non-conforming use? Yes, Attached
IV. Property Specification

1. Building Set-Back Lines
  Required Existing
a. Front: No Specific Requirements
Listed
Per Survey: 24.20 Ft. to 73.13
Ft. along Channel Island Boulevard
b. Side: 5 Ft. Per Survey: 5 Ft. along
Victoria Avenue;
24.57 Ft. along East Property
Line
c. Rear: 20 Ft. Per Survey: 23.88 Ft. to
113.97 Ft.
d. Perimeter (Street Right-of-Way and
Property Lines)
5 Ft., plus 5 Ft. for each Story
above 2nd Floor.
Per Survey: 5 Ft. along
Victoria Avenue;

24.20 Ft. along Channel
Island Boulevard

Is The Existing Building in Conformance? Yes, as to Setbacks. (See Chapter 4,
Part E, Section 10483.B.C.D and Chapter
4, Part J, Section 10582.C.1 for Code
reference)
2. Building Size
a. Maximum Building Height or Stories: 75 Ft.
b. Existing Building Height or Stories: 11.3 Ft. to 25.3 Ft. (Per Survey)
c. Building Site Area Requirements: Minimum Lot Area: 6,000 Sq. Ft.
(Existing 406,850.4 Sq. Ft.)

Minimum Lot Width: 60 Ft.

(Existing 946.00 Ft. along Channel
Island Boulevard)

Minimum Lot Depth: 100 Ft.
(Existing 430 Ft. along Victoria Avenue)

Minimum Landscaping: 20% of Net Site
Area (Existing 40%, per an approximate
scale of the Survey)

Is The Existing Building in Conformance? Yes, as to Height, Lot Area, Lot Width,
Lot Depth and Landscaping. (See
Chapter 4, Part E, Section
10483.A.E.F.G.I.2.a and Chapter 4, Part
J, Section 10582.C.2 for Code reference)
3. Density
a. Building Density Formula: Maximum Floor Area Ratio (FAR): 0.55

(Existing 116,002 / 406,850.4 = 0.28)

b. Approximate Building Footprint: 96,054 Sq. Ft. (Per Scale of the Survey)

116,002 Sq. Ft. (Per Rent Roll)

Is The Building Coverage in Conformance? Yes, as to Floor Area Ratio.

(See Chapter 4, Part E, Section 10483.H

for Code reference)

4. Parking
a. Parking Space Formula: 416 Total Parking Spaces (Per Parking
Study dated December 4, 2007, See
Attached)
b. Parking Spaces Required: 416 Total Parking Spaces
c. Existing Parking Spaces: 460 Total Parking Spaces, Including 17
Handicap Spaces (Per Survey)

465 Total Parking Spaces, Including 17

Handicap Spaces (Per a hand count of

the delineated Spaces depicted on the

Survey.)

Is The Existing Parking in Conformance? Yes, as to Parking. (See Chapter 3,

Section 10301 for Code reference and

Parking Study dated December 4, 2007

for reference.)

V. Site History
1. Was special permitting or condition(s) applied to existing zoning? Yes
a. Site Plan Approval or Planned Unit Development? Site Plan Approval
(Copy Attached)
b. Other?
Resolution No. 1542: Landscape Agreement with Sutter Hill Limited;

Permit No. PHPD -309: to replace signage with new Channel Letter Signage in a
Single-Phase as part of the Final for the Parapet Building Wall;

Resolution No. 76-1L Approving minor additions to the Planned Development
Permits;

Parking Study dated December 4, 2007. (See Attached)

2. Are there any outstanding building or zoning violations on file? According to Yvonne Gonzales, Community Development Specialist, there are no outstanding Zoning Code violations for this site.
According to research, there are no outstanding Building Code violations for this site.
3. Is a Certificate of Occupancy available for the site? Yes, attached are the Certificates of Occupancy issued for this site. Please note, the absence of a Certificate of Occupancy is not considered a violation nor will it give rise to any enforcement action affecting the property or any part thereof.
VI. Conclusions
1. Conformance Status: Legal Conforming
2. Nonconforming Characteristics of the Site Not Applicable
3. Recommended Action: Not Applicable
4. Rebuildability Clause: Not Applicable
Other Comments: No Additional Comments.
The Planning & Zoning Resource Corporation has relied on information provided by the following:
Municipal Officials
City of Port Hueneme

Greg C. Brown, Community Development
Director- 250 North Ventura Road

Port Hueneme, CA 93041

805-986-6553

Surveyor
Smith Roberts

100 NE 5th Street

Oklahoma City, OK 73104

405-840-4344

Survey Dated: 4/5/2010

This report was prepared by Susan Davis. Questions may be directed to David Anderson at 405.840.4344, Extension 3337 or by email to davida@pzr.com. Please reference PZR Site Number 12345-1.